Proceedings of thermal engineering conference
Online ISSN : 2433-1317
2001
Session ID : OS-12I/D103
Conference information
D103 Direct flowing out of cooled air from a thetmoacoustic refrigerator
Toshitsugu HARAYoshikazu MATSUMOTONoritoshi OGAWAKazuyoshi SHIMIZU
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
Experimental investigation on the phenomena of direct flowing out of cooled air from a thermoacoustic refrigerator was made. Cooled air in the acoustic refrigerator was blown naturally by pressure change in the refrigerator without any valve, the inside air was cooled by thermoacoustic effect and the air was blown out by acoustic pressure. The flow rate of the air increased with the power input to the acoustic driver and with the outlet diameter. On the other hand, the temperature difference decreased with their increase.
Content from these authors
© 2001 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top