Abstract
This report deals with deflection measurement of a inflatable membrane structure subjected to internal pressure loading. Conventionally, we have performed deflection measurement of the structure using laser displacement sensor. Lately, we introduced Kuraves which is a three-dimensional photo-grammetric system. To show the effect of the photo-grammetric system, the results is compared with using laser displacement sensor.