Abstract
This paper proposes a diagnostic method of bearing in sump pumps in nuclear power plants. The method measures the distance from the casing to the shaft by moving an ultrasonic sensor on the casing surface and diagnoses the anomaly of the bearing by solving the two dimensional movement of the shaft by analyzing the two types of outputs of the ultrasonic sensor.