Abstract
Pressure-induced temperature oscillations are measured in a tube by using a thermocouple. The measured temperature oscillations are compared with those calculated from the simultaneously measured pressure oscillations. From the difference between them, the correction factor for the thermocouple is determined. We show the frequency and working gas dependences of the correction factor. We can obtain true temperature oscillation by using the thermocouple and the correction factor.