The Proceedings of the Symposium on Stirlling Cycle
Online ISSN : 2424-2926
2013.16
Conference information
C02 Study on Performance Evaluation of the Leak-free Cooler.
Keita ISHIGAMEMasahito KAWAITOSHIAKI KenchiRyuji KIRIAKI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 49-50

Details
Abstract

Double-acting type (DA type) six cylinder Stirling engine is researched to raise the performance characteristic. On account of get a quantitative evaluation of cooler performance, thermocouple was mounted between cooler and regenerator for temperature measurement. Therefore, mounting thermocouple allowed measuring temperature of the working gas passage double-ended of cooler. The coefficient of overall heat transmission κ was able to calculate value as showing the cooler performance. In this study, we report the compared result about performance of the leak-free cooler obtained by experiment.

Content from these authors