The Proceedings of the Thermal Engineering Conference
Online ISSN : 2424-290X
2011
Session ID : C214
Conference information
C214 FEM heating analysis of resonant cavity applicator with cooling effect of blood perfusion
Jiro ArakawaSatoru KawabeYasuhiro ShindoKazuo Kato
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
This paper described heating properties of an agar phantom with cooling effect of blood perfusion. In the agar phantom, two separated blood vessels were placed. The purpose of this study is to demonstrate the cooling effect for tissue temperatures around blood vessels. We calculated temperature distributions for the phantom model with a resonant cavity by FEM. From these results, it was found that cooling effect of blood perfusion appears in the region from blood vessel approximately 1-2 cm.
Content from these authors
© 2011 The Japan Society of Mechanical Engineers
Previous article Next article
feedback