Abstract
In the present paper, flow visualization of pulsating heat pipe (PHP) made of pyrex glass tubes having internal and external diameter with 1.8 mm and 3.0 mm, respectively, was conducted to investigate flow behavior in the PHP. The working fluids were so-called Self-rewetting (SRW) fluids and pure water. SRW fluids show unique surface tension behavior which causes the fluids heat transfer enhancement. Experimental results indicated that SRW fluids remained liquid film when liquid slug moved from heating section to cooling section. Remained liquid film ruffled and formed new liquid slug which moved to cooling section.