B142 Influence of Heating Length on Entrainment in a Boiling Two-Phase Flow : Indirect evaluation based on the liquid film flow measurement
Ryuga NAKANOTakeyuki AMIHisashi UMEKAWAMamoru OZAWA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
In order to predict the liquid film dryout, estimations of evaporation of liquid film, entrainment and deposition rates, are required. In this investigation, the liquid film flow rate was measured by using the liquid film extraction method, and droplet flow rate was also estimated under thermodynamic equilibrium assumption. The qualitative applicability of this method to the boiling condition was confirmed by the experimental results. Experimental results also showed the importance of the influence of the heating on the entrainment, especially under high heat-flux condition.