Host: The Japan Society of Mechanical Engineers
Name : [in Japanese]
Date : October 22, 2016 - October 23, 2016
This paper describes thermal and installation evaluations of the double cylindrical pile heat exchangers that are used for ground source heat pump systems. Installation method of this ground heat exchanger is rotation pipe burying method, and it is possible to realize 0.6m/min and more high burying speed under soft ground condition with N value < 20. This heat exchanger has a structure of a double cylindrical heat exchanger, so it is easy to predict inner heat transfer. Due to numerical simulations, these heat exchangers is expected to be a same thermal performance as an ordinary boahole-type ground heat exchanger with same vertical length.