The Proceedings of Conference of Tohoku Branch
Online ISSN : 2424-2713
2000
Session ID : 314
Conference information
314 Mechanical Property Evaluation on Ion-Implanted Surface Layer
Takashi WAKUIMasatoshi FUTAKAWAIkuo IOKAYuji TANABE
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
This paper describes the novel technique for evaluating the mechanical properties of ion-implanted surface layer. Some constants (Young modulus(E), yield stress (σ_y), work hardening coefficient (A) and work hardening exponent (n)) in the constitutive equation assumed as the power law curve were determined by the indentation test with indenters having different tip angles. The technique is combined with a finite element method. The indentation test with a spherical indeter and its simulation analyses were performed to examine accuracy of the constitutive equation determined by the technique. Furthermore, the influences of shape of indenter on the evaluation of mechanical properties and thickness of ion-implanted surface layer were discussed.
Content from these authors
© 2000 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top