1983 Volume 32 Issue 357 Pages 615-619
This paper describes the test results on strain concentration behaviour of type 304 stainless steel and 21/4Cr-1Mo steel. Type 304 stainless steel was tested at 600°C under cyclic displacement control and cyclic load control conditions, and 21/4Cr-1Mo steel was tested at 500°C under static creep condition. An improved fine grating method was developed for this study utilizing photo spots in the indentations made by Vicker's hardness tester. The results of stain measurements were compared with the predictions by the equation given in ASME Code Case N-47 and the structural design guide for Japanese fast breader reactor. The equation was proved to give a conservative prediction.