Journal of the Society of Materials Science, Japan
Online ISSN : 1880-7488
Print ISSN : 0514-5163
ISSN-L : 0514-5163
Development of Dynamic Loading Device with Stress Sensing Block and Its Experimental Examination
Koji MIMURA, Shin HIRATA, Yoshitaka CHUMAN, Shinji TANIMURA
Author information
JOURNAL FREE ACCESS

1996 Volume 45 Issue 8 Pages 939-944

Details
Abstract
In recent years, an increasing interest has been paid for the exact measurement of stress-strain relation at high rate of strain to check the result of precise formulation of rate-sensitive constitutive equations. In the strain rate range above 102/S, the split Hopkinson bar method is commonly used for this purpose. In this method, however, the both input and output bars should be long enough to prevent the disturbance caused by the wave reflection at the ends of those two bars.
In this paper, the outline of a newly developed compact dynamic loading device using a stress sensing block which consists of a small cylindrical knob for stress measuring followed by a relatively large mass block, is drawn, and its application to the measurement of stress-strain relation at the strain rate of 103/S is discussed. With this device, the dimension of input and output bar system can be reduced to 1/2-1/3 of that of on ordinary split Hopkinson bar device, while the accuracy of the obtained stress-strain curve retains the same level of that obtained by the split Hopkinson bar device.
Content from these authors
© by The Society of Materials Science, Japan

この記事はクリエイティブ・コモンズ [表示 - 非営利 - 改変禁止 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja
Previous article Next article
feedback
Top