Journal of Japanese Society of Oral Implantology
Online ISSN : 2187-9117
Print ISSN : 0914-6695
ISSN-L : 0914-6695
The Analysis and Comparison of Bone and Commercial Synthetic Apatites Composition with Infrared Spectroscopy
Keietsu SaigoTamotsu KagayaShoko TsujimuraHaruchiyo KasaiMitsugu Suzuki
Author information
JOURNAL FREE ACCESS

1991 Volume 4 Issue 2 Pages 170-175

Details
Abstract
Hydroxyapatite is the main component of inorganic materials of bone and tooth, and has been many reported for basic examination and clinical application as medical materials. But commercial synthetic apatite component differ between companies because of its sintering or synthetic method, and its components differ from biological apatite at that.
Then, we compared apatite compositions in order to test differences between bone apatite and commercial synthetic apatite or not. The analysis of composition examined by Infrared Fourier Transform spectrometer 7000 type (made by Japan Spectroscopic Co.,Ltd.) and measured spectra subtracted from commercial synthetic apatite (Bonetite, Apaceram)to bone apatite.
As the results, 1)The composition differs from synthetic and bone apatite. 2)Furthermore, there was different compositions of commercial synthetic apatites with each other.
Accordingly, it became necessary that we should consider the differences of apatite composition in living tissue.
Content from these authors
© 1991 Japanese Society of Oral Implantology
Previous article Next article
feedback
Top