Journal of Plasma and Fusion Research
Print ISSN : 0918-7928
Plasma Sheath Formation in a Groove Target
Hiroyuki KOBAYASHI, Shigeki OHTSU, Satoru TANAKA
Author information
JOURNAL FREE ACCESS

1999 Volume 75 Issue 7 Pages 836-841

Details
Abstract
Ion and electron flux profiles could be affected by the geometric of the target. In this study, a groove target with the groove width close to the ion gyro-radius was used to investigate this effect to the sheath formation. Several other types of target were also studied for comparison. It was found that the unbalance of ion and electron fluxes induced potential differences in the targets. Due to the potential difference electric currents are generated in the targets to compensated for the differences. When insulators are inserted in the targets, the sheath potentials change to balance ion and electron fluxes at the each position in the targets.
Content from these authors
© 1999 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback
Top