Special Topic Article : Frontiers in High-Resolution X-Ray Diagnostics of Plasmas
Frontiers in High- Resolution X- Ray Diagnostics of Plasmas 6.Frontiers in X-Ray Optical Components for High-Resolution Spectroscopy and Imaging 6.1Laminar Type Varied-Line-Spacing Holographic Gratings for Soft X-Ray
Kazuo SANOMasato KOIKE
Author information
JOURNAL FREE ACCESS

2003 Volume 79 Issue 4 Pages 391-397

Details
Abstract
Laminar-type varied-line-spacing gratings have been widely used for soft x-ray monochromator recently because of the features of low stray lights and higher order lights. We have developed an advanced holographic recording and an ion-beam etching methods for the laminar type varied-line spacing gratings. This report describes a short review of the soft x-ray spectrometers using varied-line-spacing gratings, the fabrication process of the laminar-type holographic gratings, and the performance of the flat field spectrographs equipped with the laminar type varied-line spacing gratings comparing with the mechanically ruled replica gratings. It is concluded that, for the sake of the advanced design and fabrication processes and excellent spectroscopic performance, laminar-type holographic gratings will be widely used for soft x-ray spectrometers for various purposes in the near future.
Content from these authors
© 2003 by The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article