Kakuyūgō kenkyū
Online ISSN : 1884-9571
Print ISSN : 0451-2375
ISSN-L : 0451-2375
SPECTROSCOPIC MEASUREMENTS OF THE PLASMA FROM A PLASMA GUN I
SIGERU MORINOBUKI KAWASHIMAKENJI INOUEMASATOSHI TANAKA
Author information
JOURNAL FREE ACCESS

1964 Volume 13 Issue 3 Pages 324-328

Details
Abstract
Line broadenings of He I 4471 and He II 4686 in the plasma generated in a Marshall type coaxial plasma gun are measured by a 340cm Ebert type spectrometer. According to the Doppler shift measurement, a plasma is accelerated for about 5μ sec after the initiation ofthe gun discharge, and it leaves the plasma gun, while an unaccelerated plasma remains in the plasma gun after then during the discharge. Most of the line broadening in He II 4686 is due to Doppler broadening, and the Stark broadening is negligible. The accelerated plasma from the gun gradually loses the perpendicular component of the velocity to the axis of the plasma gun as it travels.
Content from these authors
© The Japan Society of Plasma Science and Nuclear Fusion Research
Previous article Next article
feedback
Top