Loading Test of Exterior Diaphragm Type Moment Connection with Circular Tube Column
Hiroki NAKAYAMAAtsushi SATOKeiichiro SUITA
Author information
JOURNAL FREE ACCESS

2011 Volume 18 Issue 72 Pages 72_53-72_60

Details
Abstract

This paper addresses the loading tests of beam-to-column connection with exterior diaphragm and circular tube column. These tests were conducted to verify the validity of the derived collapse load that was based on plastic analysis. Major findings obtained from tests are summarized as follows: (1) the test specimens of exterior diaphragm type moment connection exhibited sufficient deformation capasity until 0.1 rad drift angle, (2) the derived collapse load formula correlated well with the specimen which were connected beam flanges to diaphragms by weld.