STEEL CONSTRUCTION ENGINEERING
Online ISSN : 1884-0329
Print ISSN : 1880-9928
ISSN-L : 1880-9928
ANALYTICAL STUDY ON CRITICAL RADIUS-THICKNESS RATIO FOR STABLE HYSTERISYS OF LATTISE DAMPING WALL SYSTEM WITH TORSIONL STEEL TUBE
Takuya SUZUKIKenji YAMAZAKI
Author information
JOURNAL FREE ACCESS

2015 Volume 22 Issue 86 Pages 86_47-86_55

Details
Abstract
In this paper, a new type damping wall system using torsional steel tube damper is proposed. This proposed system has a feature that we can set the stiffness and yielding strength freely. And we can set any opening for doors or windows where designers want. For the proposed system has stable hysteretic energy absorption, it is important that steel tube damper shows stable hysteresis. But it is known that with large radios-thickness ratio, steel tube damper has small energy absorption ability. So, in this paper, the critical radios-thickness ratio of torsional steel tube damper for large energy absorption is confirmed by FE analysis.
Content from these authors
© 2015 Japanese Society of Steel Construction
Previous article Next article
feedback