STEEL CONSTRUCTION ENGINEERING
Online ISSN : 1884-0329
Print ISSN : 1880-9928
ISSN-L : 1880-9928
PERFORMANCE EVALUATION OF BUCKLING-RESTRAINED BRACES INSTALLED IN A MID-RISE STEEL STRUCTURE
Ryohei NARUIKazuhisa KOYANOMitsumasa MIDORIKAWATadao NAKAGOMIMamoru IWATA
Author information
JOURNAL FREE ACCESS

2017 Volume 24 Issue 95 Pages 95_41-95_48

Details
Abstract

Our past studies have revealed only the structural performance of the buckling-restrained brace (BRBSM) members. It is necessary to study BRBSMs in a structure.

In this paper, a model of a mid-rise steel structure with BRBSMs is analyzed. Evaluated are cumulative plastic strain energy ratios and cumulative fatigue values of BRBSMs. As a result, cumulative plastic strain energy ratios and cumulative fatigue values exceed required values to BRBSMs under a severe earthquake. BRBSM of developed high-performance type is applicable against so many repeated loadings of low strain amplitude.

Content from these authors
© 2017 Japanese Society of Steel Construction
Previous article Next article