STEEL CONSTRUCTION ENGINEERING
Online ISSN : 1884-0329
Print ISSN : 1880-9928
ISSN-L : 1880-9928
CAUSE AND COUNTERMEASURES FOR NON-DETECTION OF SPECIFIC NATURAL FREQUENCIES IN TENSION ESTIMATION OF A CABLE WITH A DAMPER
Aiko FURUKAWAKatsuya HIROSERyosuke KOBAYASHI
Author information
JOURNAL FREE ACCESS

2021 Volume 28 Issue 111 Pages 111_79-111_90

Details
Abstract

In the maintenance of cable structures such as cable-stayed bridges, it is necessary to estimate the cable tension. In current practice, the cable tension is estimated from natural frequencies using the higher-order vibration method. However, this method cannot be applied to a cable with a damper. Therefore, the authors proposed a tension estimation method for a cable with a damper in a previous study. However, it was found that the method does not work for some cases even though they are rare. This study revealed the reason why the previously proposed method does not work for some cases and proposed a method to solve this difficulty.

Content from these authors
© 2021 Japanese Society of Steel Construction
Previous article Next article
feedback
Top