STEEL CONSTRUCTION ENGINEERING
Online ISSN : 1884-0329
Print ISSN : 1880-9928
ISSN-L : 1880-9928
EVALUATION OF BOLT AXIAL TENSION FORCE AND SLIP STRENGTH FOR HIGH-STRENGTH BOLTED CONNECTIONS AFTER HEATING AND COOLING PROCESSES
Seokhyeon HANFuminobu OZAKIKenji TADAJunichi SUZUKI
Author information
JOURNAL FREE ACCESS

2022 Volume 29 Issue 115 Pages 115_13-115_24

Details
Abstract

In this study, bolt axial tension force and slip strength for high-strength bolted connections after heating and cooling processes were investigated by using an ultrasonic measuring unit and the tensile tests of the connection specimens, respectively. The measuring results on axial tension force of JIS F10T and slip strength of the connection subjected to the heat-damages were accumulated, it was, furthermore, clarified that the secondary tightening for the damaged connections was an effective repair work to recover the bolt axial tension force and the slip strength after fires.

Content from these authors
© 2022 Japanese Society of Steel Construction
Previous article Next article
feedback
Top