STEEL CONSTRUCTION ENGINEERING
Online ISSN : 1884-0329
Print ISSN : 1880-9928
ISSN-L : 1880-9928
EVALUATION METHOD OF YIELD STRENGTH OF BEAM FLANGE TO BOX-SECTION COLUMN CONNECTION CONSIDERING WELDED PARTS OF EXTERIOR DIAPHRAGM
Ryosuke OBAHiromitsu MORIOKAYuji KOETAKATatsuya NAKANOTomohiro KINOSHITA
Author information
JOURNAL FREE ACCESS

2025 Volume 31 Issue 124 Pages 124_108-124_123

Details
Abstract

This paper targets steel beam to box-section column connections with exterior diaphragms whose depth are smaller than those of conventional ones. An evaluation method of yield strength of beam flange connections is proposed considering partial penetration welds of the exterior diaphragm. Mechanical behavior and effects of parameters on yield strength of connections are examined by a loading test and finite element analysis. As a result, it is clarified that calculated values based on the evaluation method can correspond to results of the test and the analysis within ±10% errors.

Content from these authors
© Japanese Society of Steel Construction
Previous article Next article
feedback
Top