1998 Volume 5 Issue 19 Pages 97-105
Recently, mixed structure composed of reinforced concrete columns and steel beams have been used in the construction of buildings. A great number of reseach papers according to the beam-column joints also have been published for these few years. However, the stress transfer mechanism in the beam-column joints has not been clarified yet, especially in the type of through column type of joint. In this paper, a method to determine the shear force ratio between concrete part and steel part of the joint is proposed in the through column type joint based on the test results and stress transfer mechanism.