Japanese Journal of Vascular Surgery
Online ISSN : 1881-767X
Print ISSN : 0918-6778

This article has now been updated. Please use the final version.

A Case of Limb Stenosis after Endovascular Abdominal Aneurysm Repair with Powerlink®
Tsunehisa YamamotoKatsuhiko OkaOsamu SakaiTaiji WatanabeKeiichi KandaHitoshi Yaku
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 14-00066

Details
Abstract

A 67-year-old man who had a saccular abdominal aortic aneurysm (AAA) with narrow terminal aorta was underwent endovascular aortic aneurysm repair (EVAR) by Endologix Powerlink®. He complained ischemic right leg pain, one year after EVAR. The computed tomography showed stenosis of Powerlink® right limb. The right limb was compressed by the left limb of Powerlink® at narrow terminal aorta. We performed re-intervention to dilate narrow terminal aorta with Palmatz XL stent® (Cordis) and bilateral limbs with kissing stenting of Express Vascular LD® (Boston Scientific). After operation his ankle brachial pressure index arise from 0.66 to 1.19. Powerlink® is said that hard to complicate limb stenosis even if narrow terminal aorta case due to its sit on the bifurcation of aorta system. Even through, careful observation is needed at quit narrow terminal aorta cases, which may happen not to sit on stentgraft main body at terminal aorta.

Content from these authors

この記事はクリエイティブ・コモンズ [表示 - 非営利 - 継承 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by-nc-sa/4.0/deed.ja
feedback