Journal of Japan Society on Water Environment
Online ISSN : 1881-3690
Print ISSN : 0916-8958
ISSN-L : 0916-8958
ORIGINALS
Evaluation of Tap Water Quality by Spectrofluorometry
Nobuyoshi KAIGASouichiro NAKANOYoshihiko TEZUKATadahiro ISHII
Author information
JOURNAL FREE ACCESS

1999 Volume 22 Issue 1 Pages 54-60

Details
Abstract
Spectrofluorometry was applied to the detection of micropollutants in tap water. Tap water contains a small quantity of humic substances, such as chlorinated fulvic acids. Survey of tap water in various parts of Japan revealed that raw water from the river in big cities contains relatively large quantities of those substances. A part of fluorescent substances is eliminated in the purification process and it's fluorescence intensity is reduced by chlorination. Fluorescence intensity is also reduced by ozonation process, but changes little by subsequent chlorination. Thus, Ozone/AC (activated carbon) treatment enables us to reduce both fluorescence intensity and a trihalomethane formation potential. Tap waters in Japan show a lower fluorescence intensity, about 1/10 of those of various cities of the world. Although all the fluorescent substances are not always the chlorinated fulvic acid because of different disinfection processes in foreign countries, more attention should be paid to fluorescent substances in tap water.
Content from these authors
© 1999 Japan Society on Water Environment
Previous article Next article
feedback
Top