Journal of the Japan Society of Waste Management Experts
Online ISSN : 1883-163X
Print ISSN : 1883-1648
ISSN-L : 1883-1648
Paper
Air Flow Rate in Leachate Collection Pipe of Semi-Aerobic Landfills
Theoretical Study on Pipe Network
Nobutoshi TanakaToshihiko MatsutoYoungkyu Kim
Author information
JOURNAL FREE ACCESS

1997 Volume 8 Issue 1 Pages 1-8

Details
Abstract
A theoretical method is presented for numerical calculation of air flow in the leachate collection pipe network in semi-aerobic landfills. It is shown that the presented method is also effective on a complex network. The method is applied to an assumed typical landfill site and the following are obtained. 1) Maximum air temperature increase between inlet and outlet in the pipe network is a good index for comprehensively estimating the influence of thermal factors such as atmospheric temperature, temperature of pipe wall and heat transfer coefficient between the pipe wall and air in pipe. 2) The depth of the landfill has little effect on the inlet velocity of air flow. 3) The maximum of the inlet air flow rate is attained when the diameter of the main pipe is more than 1 m and enough air cannot be supplied into a leachate collection pipe network when the diameter is less than 0.4 m. 4) The less diameter of branch pipe there is, the less velocity of inlet air flow is attained. Enough air cannot be supplied when the branch diameter is less than 0.15 m. 5) Enough air can be supplied even if the distance between each branch pipe is 50 m.