Abstract
A measuring apparatus for biogas using the gravimetric method was developed and evaluated. The apparatus in this study measured biogas by the catalytic combustion of methane and measurement of the volume of CO2. The amount of methane was determined by measuring the amount of CO2. Sample biogas mixture was prepared using carbon dioxide and methane in a fixed ratio. The relationship between accuracy of measurement and combustion temperature and premixing air ratio was investigated. Results show that the measurement of carbon dioxide was highly accurate under either experimental condition. However, the measurement of methane was influenced by combustion conditions. At a temperature of 320℃ and a ratio of methane to air of 1.5-8.0 v/v%, measurement of methane was achieved with an accuracy of over 97% (within a coefficient of variation of 2.7%). Our results also showed that nearly 500ml biogas was necessary to maintain the accuracy of determination.Improved hydrogen sulfide removal is necessary for this apparatus to be applied to measurement of biogas produced by anaerobic digestion, since hydrogen sulfide influences catalysis. However, the determination of biogas after the desulfurization processing is possible if the sample contains 14.3~81.7% methane.