2011 Volume 65 Issue 3 Pages 232-236
Measuring the thickness of the web by using conventional caliper sensor has been achieved through the use of dual-side, contacting caliper sensors. Therefore, there has a problem of the flaw on the paper surface and sensor abrasion damage.
On that occasion, paper makers have been asking for a new type of caliper measurement, which overcomes the weaknesses of contacting caliper. Most of the QCS makers have been using laser sensor to measure the thickness.However,Ishinomaki Mill introduces Yokogawa's non-contact (one side light-touch) caliper sensor which is based on a combination of two techniques chromatic aberration and confocal displacement.This one can expect the improvement to eliminate the problems of the flaw and marking on the paper,sensor contact abrasion and dirt deposit on the contact.
This report presents the outline of introducing optical caliper sensor which we introduced into Ishinomaki mill N6.