Trace Nutrients Research
Online ISSN : 2436-6617
Print ISSN : 1346-2334
Proceeding
Preparation and characterization of antibody against glycyl-L-histidyl-L-lysine-copper (II) complex
Takaji SatoTomoko HaraguchiYoshihiro SaitoMasahiko Chikuma
Author information
JOURNAL FREE ACCESS

2002 Volume 19 Pages 55-58

Details
Abstract

Antiserum against gly-L-his-L-lys (GHK)-Cu2+ complex has been generated using BSA-GHK-Cu2+ conjugate as an immunogen, and an EIA for the determination of GHK -Cu2+ has been developed. The standard curve allows the determination of 8×10-7M to 1×10-5 M of GHK-Cu2+. The EIA method was applied to the determination of GHK-Cu2+ spiked in rat plasma. Recoveries from o-phenanthroline treated rat plasma were satisfactory whereas they from untreated rat plasma were low. The antiserum can bind to not only GHK-Cu2+ but also GHK, though the affinity is higher for the former than for the latter.

Content from these authors
Previous article Next article
feedback
Top