1961 Volume 27 Issue 183 Pages 1707-1716
In order to answer the question asked by Prof. T. Uematsu in the discussion as to 7th Report of this research, we made a series of experiments with water on two disc valves, one d=28mm in diameter and the other, d=30.2mm in diameter. In these experiments lifting force P and discharge Q were measured at each valve lift l and effective head H was varied in 6 stages from 194 cm down to 9cm. From the results we can presume that, even if H is considerably larger than 194cm, P/H and Q/l√H would be higher or lower than the case where H=194cm by only a few per cent, as far as cavitation does not occur.