Transactions of the Japan Society of Mechanical Engineers Series A
Online ISSN : 1884-8338
Print ISSN : 0387-5008
Analysis of the Tightening Process of Bolted Joint with Bolt Heater
Toshimichi FUKUOKAQuantuo XU
Author information
JOURNAL FREE ACCESS

1997 Volume 63 Issue 607 Pages 561-566

Details
Abstract

A boll heater is widely used for tightening large structural members that use bolts with large nominal diameters, where a high axial force is required. The actual tightening operation with the bolt heater is usually done by skilled workers, since it is fairly difficult to control the axial force with high accuracy. In this study, the fundamental characteristics of the method are clarified by experiment and analysis, and a numerical procedure for evaluating the tightening process is proposed using FEM as an elastic contact problem in the transient temperature field. The relationships between the heating operation and the axial force are obtained for various design factors. In addition, the effects of grip length of fastened plate and nut rundown torque on axial force are also discussed. The validity of the numerical method proposed here is ascertained by comparing with experimental results.

Content from these authors
© The Japan Society of Mechanical Engineers
Previous article Next article
feedback