A Large-Size Thermoacoustic Cooling System for a Practical Use (Study on Effect of Cross-Section Area of Tube on Energy Conversion into Sound from Heat)
Yuji KITADANIShin-ichi SAKAMOTOKentaro KURODAYoshiaki WATANABE
Author information
JOURNAL FREE ACCESS

2011 Volume 77 Issue 776 Pages 1021-1025

Details
Abstract

Experimental investigation of the inner diameter in the thermoacoustic cooling system was carried out to confirm the effect for energy conversion efficiency. We carried out an experiment by using the thermoacoustic cooling system with 3 type inner diameters (24 mm, 42 mm, 100 mm). As results, acoustic power and a phase difference between sound pressure and particle velocity was varied. Moreover, it was confirmed that energy conversion efficiency in it changed with the variety of inner diameter. Energy conversion efficiency in it with inner diameter 100 mm was best of all. It is considered that a factor of improvement of energy conversion efficiency was change of phase difference between the sound pressure and the particle velocity.