TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Online ISSN : 1884-8346
ISSN-L : 1884-8346
Note
Application of Inlet Fogger Cooling System for Economical Power Boosting of Gas Turbine
Tatsuro UCHIDAFumio OOTOMOHidenori FUKUTAKEMasao ITOH
Author information
JOURNAL FREE ACCESS

2013 Volume 79 Issue 799 Pages 276-280

Details
Abstract
This paper describes a gas turbine inlet air cooling system using high pressure spray nozzle. Thermal characteristics and fluid properties were studied by performing the wind tunnel test that simulated an actual gas turbine intake cooling duct part. A result of examining the cooling performance due to differences in the inlet relative humidity 30~50%RH, the cooling performance was the same. Furthermore, as a result of investigating the cooling performance due to the difference in a spray nozzle number, in one case, it became clear from 33°C that it is possible for 28°C to cool ,and in three case, it became clear from 33°C that it is possible for 23°C to cool. The air humidifying cooling process of an actual gas turbine inlet duct part was clarified.
Content from these authors
© 2013 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top