Transactions of the Japan Society of Mechanical Engineers Series B
Online ISSN : 1884-8346
Print ISSN : 0387-5016
A New Method of Liquid Crystal Thermometry Excluding Human Color Sensation : Narrow Band Optical Filter Method
Tomoaki KUNUGIMasaharu UEDANorio AKlNO
Author information
Keywords: Heat Transfer
JOURNAL FREE ACCESS

1987 Volume 53 Issue 485 Pages 241-249

Details
Abstract
Some choresteric liquid crystals can be used as a thermometer because of their color changes with varying temperatures. However, it is impossible to employ human color sensation for precise quantitative evaluation of temperature from their color. Therefore, a new method of liquid crystal thermometry is developed using narrow band optical filters and an image processor to exclude the employment of human color sensation. Relations between filter wavelength and temperature were determined by calibration tests. Two dimensional temperature distributions on a heated plate were successfully measured by the present method.
Content from these authors
© The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top