Journal of the Mass Spectrometry Society of Japan
Online ISSN : 1880-4225
Print ISSN : 1340-8097
ISSN-L : 1340-8097
Mass Spectrometric Studies of the Work Function and the Heats of Sublimation of Atom and Positive Ion
NORIAKI SASAKIKENJI KUBOMITSURU ASANO
Author information
JOURNAL FREE ACCESS

1970 Volume 18 Issue 3 Pages 1189-1194

Details
Abstract
The specially designed ion source of mass spectrometer has been used to measure simultaneously both ions formed by electron impact and by self surface ionization, and from these measurements the work functions and the heats of sublimation of atoms and positive ions of rhenium, tantalum and tungsten have been determined. These values obtained are 5.62±0.08, 7.94±0.20and10.19±0.28eV for rhenium, 5.02±0.11, 8.04±0.12and10.90±0.23eV for tantalum, and 5.04±0.29, 9.28±0.27 and 12.22±0.56eV for tungsten, respectively.