Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
REVIEWS
Clinical Applications of 4D Flow MRI in the Portal Venous System
Thekla H. OechteringGrant S. RobertsNikolaos PanagiotopoulosOliver WiebenScott B. ReederAlejandro Roldán-Alzate
Author information
JOURNAL OPEN ACCESS

2022 Volume 21 Issue 2 Pages 340-353

Details
Abstract

Evaluation of the hemodynamics in the portal venous system plays an essential role in many hepatic pathologies. Changes in portal flow and vessel morphology are often indicative of disease.Routinely used imaging modalities, such as CT, ultrasound, invasive angiography, and MRI, often focus on either hemodynamics or anatomical imaging. In contrast, 4D flow MRI facilitiates a more comprehensive understanding of pathophysiological mechanisms by simultaneously and noninvasively acquiring time-resolved flow and anatomical information in a 3D imaging volume.

Though promising, 4D flow MRI in the portal venous system is especially challenging due to small vessel calibers, slow flow velocities, and breathing motion. In this review article, we will discuss how to account for these challenges when planning and conducting 4D flow MRI acquisitions in the upper abdomen. We will address patient preparation, sequence acquisition, postprocessing, quality control, and analysis of 4D flow data.

In the second part of this article, we will review potential clinical applications of 4D flow MRI in the portal venous system. The most promising area for clinical utilization is the diagnosis and grading of liver cirrhosis and its complications. Relevant parameters acquired by 4D flow MRI include the detection of reduced or reversed flow in the portal venous system, characterization of portosystemic collaterals, and impaired response to a meal challenge. In patients with cirrhosis, 4D flow MRI has the potential to address the major unmet need of noninvasive detection of gastroesophageal varices at high risk for bleeding. This could replace many unnecessary, purely diagnostic, and invasive esophagogastroduodenoscopy procedures, thereby improving patient compliance with follow-up. Moreover, 4D flow MRI offers unique insights and added value for surgical planning and follow-up of multiple hepatic interventions, including transjugular intrahepatic portosystemic shunts, liver transplantation, and hepatic disease in children. Lastly, we will discuss the path to clinical implementation and remaining challenges.

Content from these authors
© 2022 by Japanese Society for Magnetic Resonance in Medicine

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top