Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
MAJOR PAPER
Preparation and MR Imaging Study of a Recombinant Surface Antibody Superparamagnetic Iron Oxide Nanoparticle–EPC1 Molecular Probe for Hepatic Alveolar Echinococcosis
Weili Tian, Wenchao Ji, Wenya Liu, Peng Chen , Jun Li, Xueqi Sheng, Yaomiao Dong
Author information
JOURNAL OPEN ACCESS
Supplementary material

2026 Volume 25 Issue 2 Article ID: mp.2025-0096

Details
Abstract

Purpose: To establish a new hepatic alveolar echinococcosis (HAE) model, construct an EPC1 antibody–conjugated superparamagnetic iron oxide nanoparticle (SPION) molecular probe and evaluate the probe’s efficacy in the targeted MRI of HAE.

Methods: Thirty C57 female mice (9–10 weeks; 17–22g) were used to establish an HAE model via hepatic portal vein infection. Twenty successfully HAE-modeled mice were randomly divided into a control group, which was given a simple SPION tracer, and an experimental group, which was given a complex SPION–EPC1 tracer. In addition, a blocking group (n = 5), in which mice received an excess dose of free EPC1 antibody prior to injection of the SPION–EPC1 tracer, was included to assess EPC1-dependent targeting, and a gadolinium–diethylene triamine pentaacetic acid (Gd-DTPA) group (n = 5), which received 0.1 mmol/kg of Gd-DTPA, was included to provide a reference clinical contrast agent. MRI was performed using an animal MRI scanner, and T1- and T2-weighted imaging sequences were utilized to assess lesion characteristics before and after tracer injection at 1 and 4h time points. Subsequently, T2 signal intensity, the lesion SNR, and the lesion-to-liver contrast-to-noise ratio were measured by 2 blinded physicians (>5 years experience) using ImageJ software. Comparisons were made between plain and post-injection scans at 1 and 4h. Independent sample t-tests and non-parametric tests were applied to compare signal intensities and SNR values.

Results: The SPION–EPC1 probe significantly decreased T2 signal intensity and lesion SNR in the experimental group at both 1 (T2 intensity: –24.3%; SNR: –35.2%) and 4h (T2 intensity: –23.5%; SNR: –43.1%) compared with plain scans. By contrast, the control group showed only transient decreases, with no significant differences at 4h. In the EPC1-blocking group, the T2-signal decrease at 4h was markedly attenuated compared with that of the SPION–EPC1 group and comparable to that of the SPION group, supporting EPC1-dependent targeting.

Conclusion: The SPION–EPC1 molecular probe demonstrated improved sensitivity and long-lasting effects in the MRI detection of HAE lesions, offering a promising tool for early diagnosis and the potential advancement of clinical practice in HAE imaging.

Content from these authors
© 2026 by Japanese Society for Magnetic Resonance in Medicine

This article is licensed under a Creative Commons [Attribution 4.0 International] license.
https://creativecommons.org/licenses/by/4.0/