Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
Technical Notes
Improvement of T1 Determination of Hyperpolarized 129Xe in Mouse Brain under Controlled-Flow
Atsuomi KIMURATetsuya WAKAYAMAMichiko NARAZAKIYoko KAWATATsuyoshi UEYAMAHideaki FUJIWARA
Author information
JOURNAL OPEN ACCESS

2004 Volume 3 Issue 4 Pages 199-205

Details
Abstract
The method of determining the longitudinal relaxation time of hyperpolarized 129Xe in the mouse brain has been established in vivo with the ventilation technique under controlled-flow conditions. The uptake and washout processes for nine mice were traced through observation of time-dependent changes in NMR (nuclear magnetic resonance) signal amplitudes and analyzed by means of a two-compartment model, thus providing the quantitative value of 14.1±1.6 s as the relaxation time.
Content from these authors
© 2004 by Japanese Society for Magnetic Resonance in Medicine
Previous article Next article
feedback
Top