2010 Volume 59 Issue 1 Pages 64-66
Five cases with distal femoral partial articular fracture were treated surgically using plate. They were classified into B1 (2 cases), B2 (2 cases), B3 (one case) according to AO classification.
All cases achieved good bone union. No implant-related complications were observed.