Journal of the Particle Accelerator Society of Japan
Online ISSN : 2436-1488
Print ISSN : 1349-3833
Topics
Beam Injection with a Pulsed Multi-pole Magnet in an Electron Storage Ring
Hiroyuki TAKAKI Akira UEDATakashi OBINAYukinori KOBAYASHIMiho SHIMADARyota TAKAIShinya NAGAHASHINorio NAKAMURAKentaro HARADATohru HONDATsukasa MIYAJIMA
Author information
JOURNAL FREE ACCESS

2012 Volume 8 Issue 4 Pages 218-227

Details
Abstract

As “top-up” injection is widely used in synchrotron radiation sources, it has become very important to suppress stored beam oscillation during beam injection. To minimize this oscillation, many methods have been proposed. A pulsed multi-pole magnet injection system is one of the promising candidates and has been studied for many years at KEK. In this article, we summarize this pulsed multi-pole magnet injection system focusing on the difference between the pulsed quadrupole magnet installed in the Photon Factory Advanced Ring and a pulsed sextupole magnet in the Photon Factory.

Content from these authors
© 2012 Particle Accelerator Society of Japan
Previous article Next article
feedback
Top