Abstract
A novel technique as thermal shock testing for ceramics is proposed to obtain quantitative values of thermal shock parameters of materials. A surface of constantly heated specimen in a furnace is cooled by a steady-state water-flow to remove fluctuations in heat-transfer coefficients on the surface, which fluctuations appear highly in a traditional water-quench test. Transient thermal stresses in thermal shocked specimens cooled by the water-flow are calculated numerically using an experimentally obtained relationship between heat-transfer coefficients and surface temperatures. The critical thermal stress of the specimen is calculated from the fracture time measured by means of an acoustic emission technique. This water-flow cooling technique is performed on alumina and other ceramic materials, and the thermal shock strength, R1C, is estimated as a material property.