Abstract
Density is an important physical parameter for thermal flow simulation in a melting furnace. High-temperature density of simulated radioactive waste glass was measured by Archimedean immersion method between 1083K and 1273K and by Archimedean double-bob method from 1273K to 1573K. We found that the molar volume of molten waste glass is proportional to the log of temperature.