Abstract
The equivalent circuit model about human body communication between wearable transmitter worn by a user and a stationary receiver was shown. The equivalent output impedance is composed of reactance caused by capacitive coupling among a transmitter, a receiver and human body and resistance caused by human body, but the effect of human body wasn′t shown. In this research, it was shown by the equivalent circuit model that human body has not only resistance but also reactance.