Host: The Japan Society for Precision Engineering
Name : 2024 JSPE Spring Conference
Location : [in Japanese]
Date : March 12, 2024 - March 14, 2024
Pages 764-765
Oil film thickness and metal contact ratio were measured by applying the electrical impedance method to ball screws. This time, we will explain the evaluation results with a double nut preloaded ball screw.