QUARTERLY JOURNAL OF THE JAPAN WELDING SOCIETY
Online ISSN : 2434-8252
Print ISSN : 0288-4771
Interfacial Microstructure between Copper Ribbon and Nickel-coated Copper Plate Formed by Ultrasonic Bonding
Masakatsu MaedaDaisuke YagiYasuo Takahashi
Author information
JOURNAL FREE ACCESS

2013 Volume 31 Issue 4 Pages 188s-191s

Details
Abstract

The present paper reports the bondabiliy and the interfacial microstructure between copper ribbons and nickel-coated copper plates by ultrasonic bonding. The ultrasonic bondability of copper to nickel is significantly improved by heating up to 423 K. On the other hand, the bondability of copper to itself is deteriorated by surface oxidation. It is also shown that the nickel coating suppresses the deterioration. The nickel layer at the central part of the bond area shows S-curved morphology, whereas it is torn and/or folded in the peripheral part of the bond interface, indicating that a complicated deformation is induced during bonding. Although ultrasonic bonding at 423 K allows lowering of the ultrasonic power to one-third of that required for bonding at room temperature, it is difficult to avoid tearing of the Ni layer.

Content from these authors
© 2013 by JAPAN WELDING SOCIETY
Previous article Next article
feedback
Top