1958 Volume 27 Issue 4 Pages 227-230
We measured deformations of plates shown in Fig. 2 and 3, specially in detail angular distortions due to moving heat sources (oxyacetylene flames) under various conditions (Table 1).
We discuss the characteristic elements of the angular distortions using a model shown in Fig. 5.
Next, We treat time variations of the angular distortions (Fig. 6), one of their special features is shown in Table 2.