1961 Volume 30 Issue 8 Pages 580-582
In this investigation, were studied about the structural change of the heat affected zone in titanium welds.
The structures in titanium welds were, in order from the base metal to the weld metal, α, grown α, α'+α and α' (all of these are H.C.P. structure).
The zone which were thought to have been heated about 900°C or so, was softest and the structure was grown α.
In the tensile test of titanium butt joints, the specimens were failued in this part, however the destruction had plenty of ductility.