Abstract
New bonding method and adequate joint structure for residual thermal stress relief at bonding Al2O3 tube to metal flange were investigated.
Main results obtained are as follows.
(1) Ag-Cu-Ti brazing after Cu2O+Cu plating on A12O3 tube and sandwich joint structure using assisted A12O3 tube snipped thin Kovar flange were established.
(2) It was confirmed that cavity coupler, ion accelerater tube brazed by the above mentioned method had excellent leak tight property (<1×10-9 Torr⋅l/s) and this vacuum brazing method could replace Mo-Mn process.