QUARTERLY JOURNAL OF THE JAPAN WELDING SOCIETY
Online ISSN : 2434-8252
Print ISSN : 0288-4771
Relation between Impurities (Au Plating) and Joints Quality
Influence of Plating on Micro Joints Quality
Hideaki SasakiShinichi KazuiTatsumi ShibataRyosuke Morinari
Author information
JOURNAL FREE ACCESS

1994 Volume 12 Issue 4 Pages 588-590

Details
Abstract
Parallel gap resistance welding of Ag plated 0.18 mm diameter oxygen free copper wires to Au+ Ni plated of Printed circuit boards (P/B) was investigated (concerning Au plating). The results are summarized as follows.
(1) Au plating bath for Good Micro Welding is composed Cobaltion 0.35-3 gf/l [5.9-51 mol/m3] and Nickelion 0.02-0.5 gf/l [0.34-8.5 mol/m3], after Au plate it's composition of Co 0.2-3% and Ni 0.4-2% except Au :
(2) Cobalt content and Nickel content beyond the allowable limit are Bad Welding for Au plating, they cause Blow hole in the weld fillet and decrease weld strength.
Content from these authors
© by JAPAN WELDING SOCIETY
Previous article Next article
feedback