QUARTERLY JOURNAL OF THE JAPAN WELDING SOCIETY
Online ISSN : 2434-8252
Print ISSN : 0288-4771
The Digital Length Measurement by the "Three Pixel Vector Method"
New Method in the Digital Particle Analysis
Katsunori InoueKazuo Kimura
Author information
JOURNAL FREE ACCESS

1987 Volume 5 Issue 2 Pages 229-233

Details
Abstract

In the digital particle analysis by image processing, errors generate in the measurement of the perimeter in case a figure whose size is relatively small in the frame of the whole image. These errors are caused by the size and the orientation of the figure, and are unavoidable in some cases with the usual method. The new method, called the "Three Pixels Vector Method" has been developed. The above errors can be reduced remarkably by this new method. The principle and the ability of.this method, together with the other usual methods, are described in this report.

Content from these authors
© by JAPAN WELDING SOCIETY
Previous article Next article
feedback